hl7:supply
|
|
|
R |
The
element shall be present. The moodCode attribute shall be EVN to reflect that a medical
device has been provided.
|
(IPS ice) |
@classCode
|
cs |
1 … 1 |
F |
SPLY |
@moodCode
|
cs |
1 … 1 |
F |
EVN |
hl7:templateId
|
II |
1 … 1 |
M |
|
(IPS ice) |
@root
|
uid |
1 … 1 |
F |
2.16.840.1.113883.10.22.4.26 |
hl7:id
|
II |
0 … * |
R |
This optional element identifies the provision of the device (e.g. implant procedure) |
(IPS ice) |
hl7:text
|
ED |
0 … 1 |
R |
|
(IPS ice) |
hl7:reference
|
TEL |
1 … 1 |
M |
|
(IPS ice) |
@value
|
|
1 … 1 |
R |
Reference pointing to the narrative, typically #{label}-{generated-id}, e.g. #xxx-1 |
hl7:effectiveTime
|
IVL_TS |
1 … 1 |
R |
This element provides the interval of time corresponding to the device usage by/presence
in the patient.
|
(IPS ice) |
@xsi:type
|
|
1 … 1 |
F |
IVL_TS |
hl7:low
|
TS |
1 … 1 |
R |
The lower bound of the interval represents the start date/time. |
(IPS ice) |
|
|
hl7:high
|
TS |
0 … 1 |
C |
The upper bound represents the end date/time. If it is not present, the device is
still used by or present in the patient.
|
(IPS ice) |
|
|
hl7:participant
|
|
1 … * |
R |
The device is represented as a participant in the supply structure. The following
descriptions apply to the device structure.
|
(IPS ice) |
|
|
@typeCode
|
cs |
1 … 1 |
F |
DEV |
|
Example |
<participant typeCode="DEV"> <participantRole classCode="MANU"> <id root="1.2.3.999" extension="__example_only__"/> <playingDevice classCode="DEV" determinerCode="INSTANCE"> <code code="" codeSystem=""/> <!-- ... --> </playingDevice> </participantRole></participant> |
|
Example |
Presence of implanted device not known (situation) <participant typeCode="DEV"> <participantRole classCode="MANU"> <playingDevice> <code code="000000" codeSystem="2.16.840.1.113883.6.96" displayName="Presence of implanted device not known (situation)"/> </playingDevice> <scopingEntity> <id root="2.16.840.1.113883.3.3719"/> </scopingEntity> </participantRole></participant> |
|
Example |
No implant in situ (situation) <participant typeCode="DEV"> <participantRole classCode="MANU"> <playingDevice> <code code="000000" codeSystem="2.16.840.1.113883.6.96" displayName="No implant in situ (situation)"/> </playingDevice> <scopingEntity> <id root="2.16.840.1.113883.3.3719"/> </scopingEntity> </participantRole></participant> |
hl7:participantRole
|
|
1 … 1 |
R |
|
(IPS ice) |
@classCode
|
cs |
1 … 1 |
F |
MANU |
hl7:id
|
II |
0 … * |
R |
The device ID, e.g. using UDI, is represented by the id element of the participant
role. This element is optional, as not all production identifiers (e.g., serial number,
lot/batch number, distinct identification number) may be known to the provider or
patient.
|
(IPS ice) |
|
|
|
Example |
UDI GS1: DeviceIdentifier 00844588003288, Serial# 10987654d321, Lot# 7654321D <id root="2.16.840.1.113883.3.3719" extension="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/> |
|
Example |
UDI ICCBBA: DeviceIdentifier 00844588003288 <id root="2.16.840.1.113883.3.3719" extension="A9999XYZ100T0474"/> |
|
Example |
UDI HIBCC: Serial# XYZ456789012345678, Lot# LOT123456789012345 <id root="2.16.840.1.113883.3.3719" extension="+H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C"/> |
hl7:playingDevice
|
|
1 … 1 |
R |
The playingDevice element describes the device instance. |
(IPS ice) |
@classCode
|
cs |
1 … 1 |
F |
DEV |
@determinerCode
|
cs |
1 … 1 |
F |
INSTANCE |
hl7:code
|
CE.IPS (preferred) |
1 … 1 |
R |
The device code describes the type of device (e.g. arm prosthesis, arterial stent). |
(IPS ice) |
|
|
|
CONF |
|