Back To Index  <<  Back To Templates

draft Template  IPS Radiology Result Observation Component

Id 2.16.840.1.113883.10.22.17 Effective Date 2024‑08‑04 20:18:47
Status draft Draft Version Label STU2
Name IPSRadiologyResultObservationComponent Display Name IPS Radiology Result Observation Component
Description

IPS Radiology Result Observation Component

The component carries additional detailed radiological results. Depending on it's type the code and value have different constraints to reflect proper results.

Type of result

Constraints for code (Value Set)

Value Domain value type

Observation Text

IPS Results Radiology Textual Observations

String

Observation Code

IPS Results Radiology Observation

Code

Observation Measurement, including linear, area and volume quantity measurements

IPS Results Radiology Measurement Observation

Quantity

Observation Measurement, including linear, area and volume range measurements

IPS Results Radiology Measurement Observation

Interval of quantity

Observation Measurement, including linear, area and volume ratio measurements

IPS Results Radiology Measurement Observation

Ratio of quantity

Observation Measurement, including linear, area and volume sampled data measurements

IPS Results Radiology Measurement Observation

Sample Data (Binary)

Context Parent nodes of template element with id 2.16.840.1.113883.10.22.17
Classification CDA Entry Level Template
Open/Closed Open (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 4 templates, Uses 0 templates
Used by as Name Version
2.16.840.1.113883.10.22.4.12 Containment draft IPS Radiology Result Observation (STU2) 2024‑08‑04 20:18:00
2.16.840.1.113883.10.22.4.9 link pending IPS Result Organizer (STU1) 2017‑03‑02
2.16.840.1.113883.10.22.3.14 link pending IPS Results Section (STU1) 2017‑04‑30
2.16.840.1.113883.10.22.1.1 link draft International Patient Summary (2021) 2020‑07‑14 16:08:21
Relationship Specialization: template 2.16.840.1.113883.10.12.303 CDA Observation (2005‑09‑07)
ref
ad1bbr-
Item DT Card Conf Description Label
hl7:observation
(IPSdotsent)
@classCode
cs 1 … 1 F OBS
@moodCode
cs 1 … 1 R
  CONF
The value of @moodCode shall be drawn from value set 2.16.840.1.113883.1.11.18943 x_ActMoodDocumentObservation (DYNAMIC)
hl7:templateId
II 1 … 1 R (IPSdotsent)
@root
uid 1 … 1 F 2.16.840.1.113883.10.12.303
hl7:id
II 0 … * (IPSdotsent)
Choice 1 … 1 Elements to choose from:
  • hl7:code
  • hl7:code[concat(@code, @codeSystem) = doc('include/voc-2.16.840.1.113883.11.22.66-DYNAMIC.xml')//valueSet[1]/conceptList/concept/concat(@code, @codeSystem) or @nullFlavor]
  • hl7:code[concat(@code, @codeSystem) = doc('include/voc-2.16.840.1.113883.11.22.80-DYNAMIC.xml')//valueSet[1]/conceptList/concept/concat(@code, @codeSystem) or @nullFlavor]
hl7:code
CE 0 … 1 R (IPSdotsent)
  CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.40 IPS Results Radiology Observation (DYNAMIC)
hl7:code
CE 0 … 1 R (IPSdotsent)
  CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.66 IPS Results Radiology Textual Observations (DYNAMIC)
hl7:code
CE 0 … 1 R Codes identifying numeric measurements (IPSdotsent)
  CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.80 IPS Results Radiology Measurement Observation (DYNAMIC)
hl7:text
ED 0 … 1 (IPSdotsent)
hl7:statusCode
CS 0 … 1 (IPSdotsent)
  CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.1.11.15933 ActStatus (DYNAMIC)
hl7:effectiveTime
IVL_TS 0 … 1 (IPSdotsent)
Choice 1 … 1 Elements to choose from:
  • hl7:value[@xsi:type='ST']
  • hl7:value[@xsi:type='CE.IPS']
  • hl7:value[@xsi:type='PQ']
  • hl7:value[@xsi:type='IVL_PQ']
  • hl7:value[@xsi:type='RTO_QTY_QTY']
  • hl7:value[@xsi:type='BIN']
hl7:value
ST 0 … 1 R Observation Text (IPSdotsent)
where [@xsi:type='ST']
hl7:value
CE.IPS 0 … 1 R Observation Code (IPSdotsent)
where [@xsi:type='CE.IPS']
hl7:value
PQ 0 … 1 R Observation Measurement, including linear, area and volume quantity measurements (IPSdotsent)
where [@xsi:type='PQ']
  Constraint If Observation/value is a physical quantity (xsi:type="PQ"), the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC
hl7:value
IVL_PQ 0 … 1 R Observation Measurement, including linear, area and volume range measurements (IPSdotsent)
where [@xsi:type='IVL_PQ']
  Constraint If Observation/value is a physical quantity, the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC
hl7:value
RTO_QTY_QTY 0 … 1 R Observation Measurement, including linear, area and volume ratio measurements (IPSdotsent)
where [@xsi:type='RTO_QTY_QTY']
  Constraint If Observation/value is a physical quantity, the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC
hl7:value
BIN 0 … 1 R Observation Measurement, including linear, area and volume sampled data measurements (IPSdotsent)
where [@xsi:type='BIN']