hl7:observation
|
|
|
|
|
(IPS ent) |
@classCode
|
cs |
1 … 1 |
F |
OBS |
@moodCode
|
cs |
1 … 1 |
R |
|
|
CONF |
|
hl7:templateId
|
II |
1 … 1 |
R |
|
(IPS ent) |
@root
|
uid |
1 … 1 |
F |
2.16.840.1.113883.10.12.303 |
hl7:id
|
II |
0 … * |
|
|
(IPS ent) |
Choice |
1 … 1 |
|
Elements to choose from:
- hl7:code
- hl7:code[concat(@code, @codeSystem) = doc('include/voc-2.16.840.1.113883.11.22.66-DYNAMIC.xml')//valueSet[1]/conceptList/concept/concat(@code,
@codeSystem) or @nullFlavor]
- hl7:code[concat(@code, @codeSystem) = doc('include/voc-2.16.840.1.113883.11.22.80-DYNAMIC.xml')//valueSet[1]/conceptList/concept/concat(@code,
@codeSystem) or @nullFlavor]
|
hl7:code
|
CE |
0 … 1 |
R |
|
(IPS ent) |
|
CONF |
|
hl7:code
|
CE |
0 … 1 |
R |
|
(IPS ent) |
|
CONF |
|
hl7:code
|
CE |
0 … 1 |
R |
Codes identifying numeric measurements |
(IPS ent) |
|
CONF |
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.80 IPS Results Radiology Measurement Observation (DYNAMIC)
|
|
hl7:text
|
ED |
0 … 1 |
|
|
(IPS ent) |
hl7:statusCode
|
CS |
0 … 1 |
|
|
(IPS ent) |
|
CONF |
|
hl7:effectiveTime
|
IVL_TS |
0 … 1 |
|
|
(IPS ent) |
Choice |
1 … 1 |
|
Elements to choose from:
- hl7:value[@xsi:type='ST']
- hl7:value[@xsi:type='CE.IPS']
- hl7:value[@xsi:type='PQ']
- hl7:value[@xsi:type='IVL_PQ']
- hl7:value[@xsi:type='RTO_QTY_QTY']
- hl7:value[@xsi:type='BIN']
|
hl7:value
|
ST |
0 … 1 |
R |
Observation Text |
(IPS ent) |
where [@xsi:type='ST'] |
|
hl7:value
|
CE.IPS |
0 … 1 |
R |
Observation Code |
(IPS ent) |
where [@xsi:type='CE.IPS'] |
|
hl7:value
|
PQ |
0 … 1 |
R |
Observation Measurement, including linear, area and volume quantity measurements |
(IPS ent) |
where [@xsi:type='PQ'] |
|
|
Constraint |
If Observation/value is a physical quantity (xsi:type="PQ"), the unit of measure SHALL
be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839
DYNAMIC
|
hl7:value
|
IVL_PQ |
0 … 1 |
R |
Observation Measurement, including linear, area and volume range measurements |
(IPS ent) |
where [@xsi:type='IVL_PQ'] |
|
|
Constraint |
If Observation/value is a physical quantity, the unit of measure SHALL be selected
from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC
|
hl7:value
|
RTO_QTY_QTY |
0 … 1 |
R |
Observation Measurement, including linear, area and volume ratio measurements |
(IPS ent) |
where [@xsi:type='RTO_QTY_QTY'] |
|
|
Constraint |
If Observation/value is a physical quantity, the unit of measure SHALL be selected
from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC
|
hl7:value
|
BIN |
0 … 1 |
R |
Observation Measurement, including linear, area and volume sampled data measurements |
(IPS ent) |
where [@xsi:type='BIN'] |
|