This template constrains the results of an anatomic pathology observation. The result
observation includes a statusCode to allow recording the status of an observation.
“Pending” results (e.g., a test has been run but results have not been reported yet)
should be repnresented as “active” ActStatus.
Context
Parent nodes of template element with id 2.16.840.1.113883.10.22.4.11
Classification
CDA Entry Level Template
Open/Closed
Open (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 3 templates, Uses 2 templates
<observationclassCode="OBS"moodCode="EVN"> <templateIdroot="2.16.840.1.113883.10.22.4.11"/><idroot="1.2.3.999"extension="__example only__"/><codecode="..."codeSystem="1.2.3.999"/><statusCodecode="active"/><effectiveTime> <lowvalue="20170721085407"/></effectiveTime><!-- choice: 1..1 element hl7:value element hl7:value element hl7:value --> <interpretationCodecode="CAR"displayName="Carrier"codeSystem="2.16.840.1.113883.5.83"/><methodCodecode="..."codeSystem="1.2.3.999"/><targetSiteCodecode="..."codeSystem="1.2.3.999"/><author> <!-- template 2.16.840.1.113883.10.22.4.14 'IPS Body Author' (dynamic) --> </author><referenceRange> <observationRange> <valuexsi:type="ANY"/><interpretationCodecode="N"codeSystem="2.16.840.1.113883.5.83"displayName="Normal"/></observationRange></referenceRange><entryRelationshiptypeCode="COMP"> <!-- template 2.16.840.1.113883.10.22.4.22 'IPS Comment Activity' (dynamic) --> </entryRelationship></observation>
There is an open issue with this item:
hl7ips-issue-50: VS binding missing for methodCode and targetSiteCode (Open)
Item
DT
Card
Conf
Description
Label
hl7:observation
(IPS…ion)
@classCode
cs
1 … 1
F
OBS
@moodCode
cs
1 … 1
F
EVN
hl7:templateId
II
1 … 1
M
(IPS…ion)
@root
uid
1 … 1
F
2.16.840.1.113883.10.22.4.11
hl7:id
II
0 … *
R
(IPS…ion)
hl7:code
CD.IPS
1 … 1
M
(IPS…ion)
CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.41IPS Results Observation Pathology (DYNAMIC)
hl7:statusCode
CS
1 … 1
M
(IPS…ion)
CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.4ActStatusActiveCompleted (DYNAMIC)
hl7:effectiveTime
IVL_TS
1 … 1
R
(IPS…ion)
Choice
1 … 1
Elements to choose from:
hl7:value
hl7:value
hl7:value
hl7:value
CE.IPSCWE
0 … 1
C
(IPS…ion)
CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.47IPS Results Coded Values Pathology (DYNAMIC)
hl7:value
PQ
0 … 1
C
(IPS…ion)
Constraint
If Observation/value is a physical quantity (xsi:type="PQ"), the unit of measure SHALL
be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839
DYNAMIC
hl7:value
ANY
0 … 1
C
(IPS…ion)
hl7:interpretationCode
CE.IPS
0 … 1
R
(IPS…ion)
CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.1.11.78ObservationInterpretation (DYNAMIC)